<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-06 18-18-57
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 51 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 3.9 kHz -8 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
4 kHz 72 kHz 9646 40,8978
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,5 dBr 7,52 dBr 8,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 18:18, 6.04.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (52 dBuV) Max at: 72 kHz MIN: 4 kHz % above 76 kHz: 40,8978 Acquired: 2025/04/06 18:17:53 Total samples: 9646 Equivalent time: 0:08:02 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 8,2 dBr MIN: 6,5 dBr AVE: 7,52 dBr % above 10,2 dBr: 0,0 Last value: 6,6 dBr (2025/04/06 18:17:53) Station: 96.90 MHz, signal: 4/5 (51 dBuV) 18:11 18:12 18:13 18:14 18:15 18:16 18:17 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality